Medium Voltage Cable
181 Found
Multiple
25kV 1/C 350 Kcmil CU MV-105 133% EPR
Item #: 0141902
CAT #: 350MV10525KV133%EP
UPC:
Company wide:
Multiple
15kV 1/C 350 Kcmil AL MV-105 133% EPR
Item #: 0135324
CAT #: 350MV105AL15KV133%
UPC:
Company wide:
Multiple
25kV 1/C 250 Kcmil CU MV-105 133% EPR
Item #: 0141900
CAT #: 250MV10525KV133%EP
UPC:
Company wide:
Multiple
25kV 1/C 500 Kcmil AL Primary UD 100% EPR
Item #: 1174909
CAT #: 500UD25KVEPR100%13
UPC:
Company wide:
Multiple
25kV 1/C 2/0 AWG AL Primary UD 100% EPR FN
Item #: 1174898
CAT #: 2AUD25KVEPR100%FN
UPC:
Company wide:
Multiple
15kV 1/C 2 AWG AL Primary UD 133% EPR
Item #: 0135227
CAT #: 2UD15KVEPR133%13
UPC:
Company wide:
Omni Cable
Medium Voltage Power Cable, 4/0-3, MV-105-133% Insulation, 5kV/8kV
Item #: 2140391
CAT #: MVE24/003
UPC:
Company wide:
Omni Cable
Continuously Corrugated Welded Cable (CCW) 2/3, 5/8kV, Armored
Item #: 1849233
CAT #: MVE30203
UPC:
Company wide:
Multiple
25kV 1/C 1000 Kcmil CU MV-105 133% EPR
Item #: 0141905
CAT #: 1000MV10525KV133%E
UPC:
Company wide:
Multiple
35kV 1/C 1/0 AWG AL Primary UD 100% EPR
Item #: 0141529
CAT #: 1AUD35KVEPR100%13
UPC:
Company wide:
Multiple
35kV 1/C 4/0 AWG AL MV-105 133% EPR
Item #: 0141928
CAT #: 4AMV105AL35KV133%E
UPC:
Company wide:
Multiple
25kV 1/C 1/0 AWG AL Primary UD 100% EPR FN
Item #: 0139872
CAT #: 1AUD25KVEPR100%FN
UPC:
Company wide:
Multiple
35kV 1/C 1000 Kcmil CU MV-105 133% EPR
Item #: 0141924
CAT #: 1000MV10535KV133%E
UPC:
Company wide:
Multiple
25kV/35KV 1/C 500 MCM CU MV-105 133% EPR
Item #: 1174788
CAT #: 500MV1052535KV133%
UPC:
Company wide:
Multiple
25kV 1/C 750 Kcmil CU MV-105 133% EPR
Item #: 0141904
CAT #: 750MV10525KV133%EP
UPC:
Company wide:
Multiple
15kV 1/C 1000 Kcmil AL Primary UD 133% EPR
Item #: 0135243
CAT #: 1000UD15KVEPR133%1
UPC:
Company wide:
Multiple
25kV 1/C 2/0 AWG AL Primary UD 100% EPR
Item #: 1174906
CAT #: 2AUD25KVEPR100%13
UPC:
Company wide:
Multiple
25kV/35kV 1/C 1000 MCM CU MV-105 133% EPR
Item #: 1174806
CAT #: 1000MV1052535KV133
UPC:
Company wide:
Multiple
25kV 1/C 1/0 AWG AL Primary UD 100% EPR
Item #: 1174905
CAT #: 1AUD25KVEPR100%13
UPC:
Company wide:
Multiple
5/8kV 1/C 350 Kcmil CU MV-105 133% EPR
Item #: 0135264
CAT #: 350MV10558KV115MEP
UPC:
Company wide:
Multiple
25kV 1/C 250 Kcmil AL Primary UD 100% EPR FN
Item #: 1174900
CAT #: 250UD25KVEPR100%FN
UPC:
Company wide:
Multiple
35kV 1/C 750 Kcmil CU MV-105 133% EPR
Item #: 0141923
CAT #: 750MV10535KV133%EP
UPC:
Company wide:
Multiple
25kV 1/C 350 Kcmil CU MV-105 133% EPR
25kV, 1/C, 350 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.31 - 1.41".
Item #: 0141902
CAT #: 350MV10525KV133%EP
UPC:
Category:
25 kV Copper MV-105
Company wide:
Multiple
15kV 1/C 350 Kcmil AL MV-105 133% EPR
15kV, 1/C, 350 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.07 - 1.15".
Item #: 0135324
CAT #: 350MV105AL15KV133%
UPC:
Category:
15 kV Aluminum MV-105
Company wide:
Multiple
25kV 1/C 250 Kcmil CU MV-105 133% EPR
25kV, 1/C, 250 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.21 - 1.31".
Item #: 0141900
CAT #: 250MV10525KV133%EP
UPC:
Category:
25 kV Copper MV-105
Company wide:
Multiple
Bronco
25kV/35kV, 1/C, 1000 MCM, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.76 - 1.86".
Item #: 1174826
CAT #: 1000MV105AL2535KV
UPC:
Category:
25 / 35 kV Aluminum MV-105
Company wide:
Multiple
25kV 1/C 500 Kcmil AL Primary UD 100% EPR
25kV 1/C 500 Kcmil AL, Primary Underground Distribution Cable (UD), 100.% Amorphous EPR Insulation (260MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 1.36".
Item #: 1174909
CAT #: 500UD25KVEPR100%13
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
Bronco
25kV/35KV, 1/C, 2/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.06 - 1.16".
Item #: 1174819
CAT #: 2AMV105AL2535KV133
UPC:
Category:
25 / 35 kV Aluminum MV-105
Company wide:
Multiple
25kV 1/C 2/0 AWG AL Primary UD 100% EPR FN
25kV 1/C 2/0 AWG AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (260MIL), Full Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 1.09".
Item #: 1174898
CAT #: 2AUD25KVEPR100%FN
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
15kV 1/C 2 AWG AL Primary UD 133% EPR
15kV 1/C 2 AWG AL, Primary Underground Distribution Cable (UD), 133% Amorphous EPR Insulation (220MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 0.76".
Item #: 0135227
CAT #: 2UD15KVEPR133%13
UPC:
Category:
15 kV Primary UD Cable
Company wide:
Omni Cable
Medium Voltage Power Cable, 4/0-3, MV-105-133% Insulation, 5kV/8kV
Medium Voltage Power Cable, 4/0 AWG, 3 Condutor, MV-105-133% Insulation, 5kV/8kV
Item #: 2140391
CAT #: MVE24/003
UPC:
Category:
5 / 8 kV Copper MV-105
Company wide:
Omni Cable
Continuously Corrugated Welded Cable (CCW) 2/3, 5/8kV, Armored
Continuously Corrugated Welded Cable (CCW) 2/3, 5/8kV, Armored, Shielded, Variable Frequency Drive Cable, EPR Insulation, PVC Jacket
Item #: 1849233
CAT #: MVE30203
UPC:
Category:
5 / 8 kV Copper MV-105
Company wide:
Multiple
25kV 1/C 1000 Kcmil CU MV-105 133% EPR
25kV, 1/C, 1000 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.76 - 1.86".
Item #: 0141905
CAT #: 1000MV10525KV133%E
UPC:
Category:
25 kV Copper MV-105
Company wide:
Multiple
35kV 1/C 1/0 AWG AL Primary UD 100% EPR
35kV 1/C 1/0 AWG AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (345MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 1.10".
Item #: 0141529
CAT #: 1AUD35KVEPR100%13
UPC:
Category:
35 kV Primary UD Cable
Company wide:
Multiple
35kV 1/C 4/0 AWG AL MV-105 133% EPR
35kV, 1/C, 4/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.30 - 1.40".
Item #: 0141928
CAT #: 4AMV105AL35KV133%E
UPC:
Category:
35 kV Aluminum MV-105
Company wide:
Multiple
25kV 1/C 1/0 AWG AL Primary UD 100% EPR FN
25kV 1/C 1/0 AWG AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (260MIL), Full Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 0.92".
Item #: 0139872
CAT #: 1AUD25KVEPR100%FN
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
35kV 1/C 1000 Kcmil CU MV-105 133% EPR
35kV, 1/C, 1000 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.90 - 2.01".
Item #: 0141924
CAT #: 1000MV10535KV133%E
UPC:
Category:
35 kV Copper MV-105
Company wide:
Multiple
25kV/35KV 1/C 500 MCM CU MV-105 133% EPR
25KV/35KV, 1/C, 500 MCM Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.43 - 1.53".
Item #: 1174788
CAT #: 500MV1052535KV133%
UPC:
Category:
25 / 35 kV Copper MV-105
Company wide:
Multiple
25kV 1/C 750 Kcmil CU MV-105 133% EPR
25kV, 1/C, 750 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.61 - 1.71".
Item #: 0141904
CAT #: 750MV10525KV133%EP
UPC:
Category:
25 kV Copper MV-105
Company wide:
Multiple
15kV 1/C 1000 Kcmil AL Primary UD 133% EPR
15kV 1/C 1000 Kcmil AL, Primary Underground Distribution Cable (UD), 133% Amorphous EPR Insulation (220MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 1.64".
Item #: 0135243
CAT #: 1000UD15KVEPR133%1
UPC:
Category:
15 kV Primary UD Cable
Company wide:
Multiple
25kV 1/C 2/0 AWG AL Primary UD 100% EPR
25kV 1/C 2/0 AWG AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (260MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 0.97".
Item #: 1174906
CAT #: 2AUD25KVEPR100%13
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
25kV/35kV 1/C 1000 MCM CU MV-105 133% EPR
25KV/35KV, 1/C, 1000 MCM Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.76 - 1.86".
Item #: 1174806
CAT #: 1000MV1052535KV133
UPC:
Category:
25 / 35 kV Copper MV-105
Company wide:
Multiple
25kV 1/C 1/0 AWG AL Primary UD 100% EPR
25kV 1/C 1/0 AWG AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (260MIL), 1/3 Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 0.92".
Item #: 1174905
CAT #: 1AUD25KVEPR100%13
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
5/8kV 1/C 350 Kcmil CU MV-105 133% EPR
5/8kV, 1/C, 350 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 0.87 - 0.94".
Item #: 0135264
CAT #: 350MV10558KV115MEP
UPC:
Category:
5 / 8 kV Copper MV-105
Company wide:
Multiple
25kV 1/C 250 Kcmil AL Primary UD 100% EPR FN
25kV 1/C 250 Kcmil AL, Primary Underground Distribution Cable (UD), 100% Amorphous EPR Insulation (260MIL), Full Concentric Neutral, LDPE Jacket W/ 3 Red Stripes. Insulation O.D.: 1.02".
Item #: 1174900
CAT #: 250UD25KVEPR100%FN
UPC:
Category:
25 kV Primary UD Cable
Company wide:
Multiple
35kV 1/C 750 Kcmil CU MV-105 133% EPR
35kV, 1/C, 750 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.75 - 1.86".
Item #: 0141923
CAT #: 750MV10535KV133%EP
UPC:
Category:
35 kV Copper MV-105
Company wide:
181 Items found