• Search
  • "isr-250c"

"isr-250c"

277 Found
Multiple

Aluminum MV-105 Power Distribution Cable, 1/0 AWG, 25kV/35kV

Item #: 1174816
CAT #: 1AMV105AL2535KV133
UPC:
Company wide:
Multiple

25kV 1/C 4/0 AWG AL MV-105 133% EPR

Item #: 0141909
CAT #: 4AMV105AL25KV133%E
UPC:
Company wide:
Multiple

15kV 1/C 2/0 AWG AL MV-105 133% EPR

Item #: 0141907
CAT #: 1AMV105AL25KV133%E
UPC:
Company wide:
Multiple

25kV 1/C 1/0 AWG CU MV-105 133% EPR

Item #: 0141896
CAT #: 1AMV10525KV133%EPR
UPC:
Company wide:
Multiple

Sparate

Item #: 0135323
CAT #: 250MV105AL15KV133%
UPC:
Company wide:
Multiple

Osprey

Item #: 1174820
CAT #: 4AMV105AL2535KV133
UPC:
Company wide:
Multiple

35kV 1/C 350 Kcmil AL MV-105 133% EPR

Item #: 0141930
CAT #: 350MV105AL35KV133%
UPC:
Company wide:
Multiple

35kV 1/C 500 Kcmil AL MV-105 133% EPR

Item #: 0141931
CAT #: 500MV105AL35KV133%
UPC:
Company wide:
Multiple

15kV 1/C 500 Kcmil CU MV-105 133% EPR

Item #: 1174782
CAT #: 2AMV1052535KV133%
UPC:
Company wide:
Multiple

25kV/35kV 1/C 500 MCM AL MV-105 133% EPR

Item #: 1174824
CAT #: 500MV105AL2535KV13
UPC:
Company wide:
Multiple

5/8kV 1/C 2 AWG AL MV-105 133% EPR

Item #: 0135280
CAT #: 2MV10558KVAL115MEP
UPC:
Company wide:
Multiple

5/8kV 1/C 1000 Kcmil CU MV-105 133% EPR

Item #: 0135274
CAT #: 1000MV10558KV115ME
UPC:
Company wide:
Multiple

1AMV105AL15KV133%E

Item #: 0135320
CAT #: 1AMV105AL15KV133%E
UPC:
Company wide:
Multiple

25kV 1/C 1 AWG CU MV-105 133% EPR

Item #: 0141769
CAT #: 1MV10525KV133%EPR
UPC:
Company wide:
Multiple

25kV 1/C 1 AWG AL MV-105 133% EPR

Item #: 0141906
CAT #: 1MV105AL25KV133%EP
UPC:
Company wide:
Multiple

15kV 1/C 2/0 AWG CU MV-105 133% EPR

Item #: 0066284
CAT #: 2A3ACCLAMXLPX500
UPC: 980120588506
Company wide:
Multiple

5/8kV 1/C 350 Kcmil AL MV-105 133% EPR

Item #: 0135307
CAT #: 350MV10558KVAL115M
UPC:
Company wide:
Multiple

5/8kV 1/C 4 AWG AL MV-105 133% EPR

Item #: 0135278
CAT #: 4MV10558KVAL115MEP
UPC:
Company wide:
Multiple

25kV/35KV 1/C 350 MCM CU MV-105 133% EPR

Item #: 1174786
CAT #: 350MV1052535KV133%
UPC:
Company wide:
Multiple

5/8kV 1/C 350 Kcmil CU MV-105 133% EPR

Item #: 0135329
CAT #: 1000MV105AL15KV133
UPC:
Company wide:
Multiple

5/8kV 1/C 1000 Kcmil AL MV-105 133% EPR

Item #: 0135311
CAT #: 1000MV10558KVAL115
UPC:
Company wide:
Multiple

15kV 1/C 1/0 AWG CU MV-105 133% EPR

Item #: 0162843
CAT #: 3A3ACSRMURX1300
UPC: 980120587035
Company wide:
Multiple

5/8kV 1/C 4/0 AWG CU MV-105 133% EPR

Item #: 1441285
CAT #: 5565ACSR
UPC:
Company wide:
Multiple

15kV 1/C 1/0 AWG CU MV-105 133% EPR

Item #: 0419305
CAT #: 477ACSRPELICAN
UPC:
Company wide:
Multiple

Aluminum MV-105 Power Distribution Cable, 1/0 AWG, 25kV/35kV

25kV/35kV, 1/C, 1/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.02 - 1.12".
Item #: 1174816
CAT #: 1AMV105AL2535KV133
UPC:
Company wide:
Multiple

25kV 1/C 4/0 AWG AL MV-105 133% EPR

25kV, 1/C, 4/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.16 - 1.26".
Item #: 0141909
CAT #: 4AMV105AL25KV133%E
UPC:
Company wide:
Multiple

15kV 1/C 2/0 AWG AL MV-105 133% EPR

25kV, 1/C, 1/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.02 - 1.12".
Item #: 0141907
CAT #: 1AMV105AL25KV133%E
UPC:
Company wide:
Multiple

25kV 1/C 1/0 AWG CU MV-105 133% EPR

25KV, 1/C, 1/0 AWG Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.02 - 1.12".
Item #: 0141896
CAT #: 1AMV10525KV133%EPR
UPC:
Company wide:
Multiple

Sparate

15kV, 1/C, 250 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 0.97 - 1.06".
Item #: 0135323
CAT #: 250MV105AL15KV133%
UPC:
Company wide:
Multiple

Osprey

25kV/35kV, 1/C, 4/0 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.16 - 1.26".
Item #: 1174820
CAT #: 4AMV105AL2535KV133
UPC:
Company wide:
Multiple

35kV 1/C 350 Kcmil AL MV-105 133% EPR

35kV, 1/C, 350 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.45 - 1.55".
Item #: 0141930
CAT #: 350MV105AL35KV133%
UPC:
Company wide:
Multiple

35kV 1/C 500 Kcmil AL MV-105 133% EPR

35kV, 1/C, 500 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.57 - 1.67".
Item #: 0141931
CAT #: 500MV105AL35KV133%
UPC:
Company wide:
Multiple

15kV 1/C 500 Kcmil CU MV-105 133% EPR

25KV/35KV, 1/C, 2/0 AWG Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.06 - 1.16".
Item #: 1174782
CAT #: 2AMV1052535KV133%
UPC:
Company wide:
Multiple

25kV/35kV 1/C 500 MCM AL MV-105 133% EPR

25kV/35kV, 1/C, 500 MCM, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.43 - 1.53".
Item #: 1174824
CAT #: 500MV105AL2535KV13
UPC:
Company wide:
Multiple

5/8kV 1/C 2 AWG AL MV-105 133% EPR

5/8kV, 1/C, 2 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.51 - 0.59".
Item #: 0135280
CAT #: 2MV10558KVAL115MEP
UPC:
Company wide:
Multiple

5/8kV 1/C 1000 Kcmil CU MV-105 133% EPR

5/8kV, 1/C, 1000 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.32 - 1.40".
Item #: 0135274
CAT #: 1000MV10558KV115ME
UPC:
Company wide:
Multiple

1AMV105AL15KV133%E

5/8kV, 1/C, 1/0 AWG, Aluminum MV-105 Power Distribution Cable, PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.58 - 0.65".
Item #: 0135320
CAT #: 1AMV105AL15KV133%E
UPC:
Company wide:
Multiple

25kV 1/C 1 AWG CU MV-105 133% EPR

25KV, 1/C, 1 AWG Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.97 - 1.07".
Item #: 0141769
CAT #: 1MV10525KV133%EPR
UPC:
Company wide:
Multiple

25kV 1/C 1 AWG AL MV-105 133% EPR

25kV, 1/C, 1 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.97 - 1.07".
Item #: 0141906
CAT #: 1MV105AL25KV133%EP
UPC:
Company wide:
Multiple

15kV 1/C 2/0 AWG CU MV-105 133% EPR

15KV, 1/C, 2/0 AWG Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circuit: 250C, Cut to Length.
Item #: 0066284
CAT #: 2A3ACCLAMXLPX500
UPC: 980120588506
Category: ACSR
Company wide:
Multiple

5/8kV 1/C 350 Kcmil AL MV-105 133% EPR

5/8kV, 1/C, 350 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 0.87 - 0.94".
Item #: 0135307
CAT #: 350MV10558KVAL115M
UPC:
Company wide:
Multiple

5/8kV 1/C 4 AWG AL MV-105 133% EPR

Medium Voltage Cable, 5/8kV, 1/C, 4 AWG, Aluminum MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.46 - 0.53".
Item #: 0135278
CAT #: 4MV10558KVAL115MEP
UPC:
Company wide:
Multiple

25kV/35KV 1/C 350 MCM CU MV-105 133% EPR

25KV/35KV, 1/C, 350 MCM Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (320MIL), Rated for Wet/Dry Locations Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC MAX, Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 1.31 - 1.41".
Item #: 1174786
CAT #: 350MV1052535KV133%
UPC:
Company wide:
Multiple

5/8kV 1/C 350 Kcmil CU MV-105 133% EPR

5/8kV, 1/C, 350 Kcmil Copper, MV-105 Power Distribution Cable, With Copper-Tape Sheild & PVC JCKT, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 0.87 - 0.94".
Item #: 0135329
CAT #: 1000MV105AL15KV133
UPC:
Company wide:
Multiple

5/8kV 1/C 1000 Kcmil AL MV-105 133% EPR

5/8kV, 1/C, 1000 Kcmil Aluminum, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Order. Insulation O.D. Range: 1.32 - 1.40".
Item #: 0135311
CAT #: 1000MV10558KVAL115
UPC:
Company wide:
Multiple

15kV 1/C 1/0 AWG CU MV-105 133% EPR

15kV, 1/C, 1/0 AWG, Copper MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length.
Item #: 0162843
CAT #: 3A3ACSRMURX1300
UPC: 980120587035
Category: ACSR
Company wide:
Multiple

5/8kV 1/C 4/0 AWG CU MV-105 133% EPR

5/8kV, 1/C, 4/0 AWG, Copper MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duck, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circut: 250C, Cut to Length. Insulation O.D. Range: 0.72 - 0.79".
Item #: 1441285
CAT #: 5565ACSR
UPC:
Category: ACSR
Company wide:
Multiple

15kV 1/C 1/0 AWG CU MV-105 133% EPR

15kV, 1/C, 1/0 AWG Copper, MV-105 Power Distribution Cable, With Copper-Tape Shield & PVC Jacket, 133% EPR Insulation (220MILS), Rated for Wet/Dry Locations, Cable Trays, Raceway, Duct, Open Air, Direct Bury, as Permitted by NEC, Max Conductor Operation Temp: Normal: 105C, Emergency: 140C, Short Circuit: 250C, Cut to Length
Item #: 0419305
CAT #: 477ACSRPELICAN
UPC:
Category: ACSR
Company wide:
277 Items found