• Search
  • "acs880-01-361a-5"

"acs880-01-361a-5"

1,544 Found
ABB

200A OUTDOOR 5-MTR MOD

Item #: 1611196
CAT #: TMM6520R
UPC: 783164194968
Company wide:
ABB

Bulb, 24V AC/DC, 5 Watt

Item #: 0462030
CAT #: KLB24
UPC: 320500206239
Company wide:
ABB

Breaker, Miniature, 2P, 5A, 120/240VAC, 10kAIC, DIN Rail Mount

Item #: 1615604
CAT #: EP102ULD05
UPC: 413656869646
Company wide:
ABB

3.5 - 5.0 Amp, IEC, Overload Relay

Item #: 0750440
CAT #: TA25DU5.0-20
UPC: 013614376546
Company wide:
ABB

Shaft Adapter

Item #: 0828439
CAT #: SHAFTADAPTER56
UPC: 804325431194
Company wide:
ABB

Disconnect Switch, Non-Fusible, 6P, 6 Wire, 100A, 600VAC, NEMA 12

Item #: 1616195
CAT #: THN6663
UPC: 783164121179
Company wide:
ABB

ABB YPAC880-34-260A-5

Item #: 2188113
CAT #: YPAC880-34-260A-5
UPC:
Company wide:
ABB

Disconnect Switch, Non-Fusible, 6P, 6 Wire, 30A, 600VAC, NEMA 12

Item #: 1616187
CAT #: THN6661
UPC: 783164121155
Company wide:
ABB

ABB A1A050TW A1A 100 TMF 50-500 3P

Item #: 0424439
CAT #: A1A050TW
UPC:
Company wide:
ABB

Dcs800, 150hp, 0260 Kva, S02 -module, 480 Vac

Item #: 0775346
CAT #: DCS800-S02-0260-05+S204
UPC: 662348074688
Company wide:
ABB

C-2000 PUSH BUTTONS

Item #: 1881091
CAT #: P9MSMY0N
UPC: 017018843505
Company wide:
ABB

Dcs800, 75hp, 0125 Kva, S01 -module, 480 Vac

Item #: 0715283
CAT #: DCS800-S01-0125-05
UPC:
Company wide:
ABB

Dcs800, 50hp, 0100 Kva, S02 -module, 480 Vac

Item #: 0865092
CAT #: DCS800-S02-0100-05+J409
UPC: 662348074459
Company wide:
ABB

Abb Dcs800-s01-0740-05+s171 Dcs800

Item #: 0785429
CAT #: DCS800-S01-0740-05+S171
UPC:
Company wide:
ABB

Dcs800, 10hp, 0025 Kva, S02 -module, 480 Vac

Item #: 0707268
CAT #: DCS800-S02-0025-05
UPC:
Company wide:
ABB

Dcs800, 25hp, 0045 Kva, S01 -module, 480 Vac

Item #: 0818486
CAT #: DCS800-S01-0045-05
UPC:
Company wide:
ABB

Dcs800, 75hp, 0140 Kva, S02 -module, 480 Vac

Item #: 0705666
CAT #: DCS800-S02-0140-05
UPC:
Company wide:
ABB

Dcs800, 300hp, 0520 Kva, S02 -module, 480 Vac

Item #: 0886168
CAT #: DCS800-S02-0520-05 DCS800
UPC:
Company wide:
ABB

Dcs800, 125hp, 0230 Kva, S01 -module, 480 Vac

Item #: 0755664
CAT #: DCS800-S01-0230-05
UPC:
Company wide:
ABB

Dcs800, 250hp, 0450 Kva, S02 -module, 480 Vac

Item #: 0781471
CAT #: DCS800-S02-0450-05
UPC:
Company wide:
ABB

Dcs800, 150hp, 0315 Kva, S01 -module, 480 Vac

Item #: 0790271
CAT #: DCS800-S01-0315-05
UPC:
Company wide:
ABB

200A OUTDOOR 5-MTR MOD

GED TMM6520R 200A OUTDOOR 5-MTR MOD
Item #: 1611196
CAT #: TMM6520R
UPC: 783164194968
Company wide:
ABB

Bulb, 24V AC/DC, 5 Watt

Bulb, 24V AC/DC, 5 Watt, Ba 15d, 42mm. For use in Permanent or Blinking applications with K70 Series Stack Lights.
Item #: 0462030
CAT #: KLB24
UPC: 320500206239
Company wide:
ABB

Breaker, Miniature, 2P, 5A, 120/240VAC, 10kAIC, DIN Rail Mount

Breaker, 2-Pole, 5 Amp, 120/240 Volt AC, Miniature, DIN Rail Mount, 10 kAIC, D Trip Curve, 6 per Package
Item #: 1615604
CAT #: EP102ULD05
UPC: 413656869646
Company wide:
ABB

3.5 - 5.0 Amp, IEC, Overload Relay

3.5 - 5.0 Amp, IEC, Overload Relay, Type: Thermal Bi-Metallic, Trip Class 20. Selectable Manual or Automatic Reset. For use with A-Line Series, A/AE/AL9 - A/AE/AL40 Frame Contactors.
Item #: 0750440
CAT #: TA25DU5.0-20
UPC: 013614376546
Company wide:
ABB

Shaft Adapter

Shaft Adapter. Use adapter 5 mm Shafts with 6 mm Disconnects and Handles.
Item #: 0828439
CAT #: SHAFTADAPTER56
UPC: 804325431194
Company wide:
ABB

Disconnect Switch, Non-Fusible, 6P, 6 Wire, 100A, 600VAC, NEMA 12

Disconnect Switch, Heavy Duty, Non-Fusible, 6-Pole, 6 Wire, 100 Amp, 600 Volt AC, NEMA 1/3R/5/12
Item #: 1616195
CAT #: THN6663
UPC: 783164121179
Company wide:
ABB

ABB YPAC880-34-260A-5

ABB YPAC880-34-260A-5
Item #: 2188113
CAT #: YPAC880-34-260A-5
UPC:
Company wide:
ABB

Disconnect Switch, Non-Fusible, 6P, 6 Wire, 30A, 600VAC, NEMA 12

Disconnect Switch, Heavy Duty, Non-Fusible, 6-Pole, 6 Wire, 30 Amp, 600 Volt AC, NEMA 1/3R/5/12
Item #: 1616187
CAT #: THN6661
UPC: 783164121155
Company wide:
ABB

ABB A1A050TW A1A 100 TMF 50-500 3P

ABB A1A050TW A1A 100 TMF 50-5
Item #: 0424439
CAT #: A1A050TW
UPC:
Company wide:
ABB

Dcs800, 150hp, 0260 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 208 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 125 Hp; Frame Size: D2; Ac Input Contactors 3-pole(no): A210-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0775346
CAT #: DCS800-S02-0260-05+S204
UPC: 662348074688
Company wide:
ABB

C-2000 PUSH BUTTONS

ABB P9M-SMY0N 5 POS SEL SW;MA
Item #: 1881091
CAT #: P9MSMY0N
UPC: 017018843505
Company wide:
ABB

Dcs800, 75hp, 0125 Kva, S01 -module, 480 Vac

Abb; 3-phase Converter Module; Non-regenerative (2-q); Voltage Rating: 230 - 525vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature With Rated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Cooling Air Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C): 5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct, No Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 111 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 60 Hp; Frame Size: D1; Ac Input Contactors 3-pole (no): A110-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0715283
CAT #: DCS800-S01-0125-05
UPC:
Company wide:
ABB

Dcs800, 50hp, 0100 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 84 Amp Dc; Standardduty Us 150%, 30 Sec, Psd: 50 Hp; Frame Size: D1; Ac Input Contactors 3-pole (no): A75-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0865092
CAT #: DCS800-S02-0100-05+J409
UPC: 662348074459
Company wide:
ABB

Abb Dcs800-s01-0740-05+s171 Dcs800

Abb; 3-phase Converter Module; Non-regenerative (2-q); Voltage Rating: 230 - 525vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature With Rated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Cooling Air Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C): 5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct, No Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 670 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 400 Hp; Frame Size: D4; Fan Voltage: 120 Vac; Ac Input Contactors 3-pole (no): Af750-30-11-70; Short Circuit Current Rating: 65kamp
Item #: 0785429
CAT #: DCS800-S01-0740-05+S171
UPC:
Company wide:
ABB

Dcs800, 10hp, 0025 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 20 Amp Dc; Standardduty Us 150%, 30 Sec, Psd: 10 Hp; Frame Size: D1; Ac Input Contactors 3-pole (no): A12-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0707268
CAT #: DCS800-S02-0025-05
UPC:
Company wide:
ABB

Dcs800, 25hp, 0045 Kva, S01 -module, 480 Vac

Abb; 3-phase Converter Module; Non-regenerative (2-q); Voltage Rating: 230 - 525vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature With Rated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Cooling Air Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C): 5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct, No Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 38 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 20 Hp; Frame Size: D1; Ac Input Contactors 3-pole (no): A30-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0818486
CAT #: DCS800-S01-0045-05
UPC:
Company wide:
ABB

Dcs800, 75hp, 0140 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 125 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 75 Hp; Frame Size: D1; Ac Input Contactors 3-pole (no): A110-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0705666
CAT #: DCS800-S02-0140-05
UPC:
Company wide:
ABB

Dcs800, 300hp, 0520 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 405 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 250 Hp; Frame Size: D3; Ac Input Contactors 3-pole(no): Af400-30-11-70; Short Circuit Current Rating: 65 Kamp
Item #: 0886168
CAT #: DCS800-S02-0520-05 DCS800
UPC:
Company wide:
ABB

Dcs800, 125hp, 0230 Kva, S01 -module, 480 Vac

Abb; 3-phase Converter Module; Non-regenerative (2-q); Voltage Rating: 230 - 525vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature With Rated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Cooling Air Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C): 5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct, No Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 205 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 125 Hp; Frame Size: D2; Ac Input Contactors 3-pole (no): A210-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0755664
CAT #: DCS800-S01-0230-05
UPC:
Company wide:
ABB

Dcs800, 250hp, 0450 Kva, S02 -module, 480 Vac

Abb; 3-phase Converter Module; Regenerative (4-q); Voltage Rating: 230 - 525 Vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature Withrated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Coolingair Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C):5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct,no Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000 Mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 360 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 200 Hp; Frame Size: D3; Ac Input Contactors 3-pole(no): Af400-30-11-70; Short Circuit Current Rating: 65 Kamp
Item #: 0781471
CAT #: DCS800-S02-0450-05
UPC:
Company wide:
ABB

Dcs800, 150hp, 0315 Kva, S01 -module, 480 Vac

Abb; 3-phase Converter Module; Non-regenerative (2-q); Voltage Rating: 230 - 525vac/500 Vdc; Environmental Conditions: Permissible Cooling Air Temperature At Converter Module Air Inlet: 0 To +55 Deg C; Permissible Cooling Air Temperature With Rated Dc Current: 0 To +40 Deg C; Permissible Cooling Air Temperature With Different Dc Current: +40 To +55 Deg C Derating (1 Pct/1 Deg C); Permissible Cooling Air Temperature Options: 0 To +40 Deg C; Relative Humidity (at 5 To +40 Deg C): 5 To 95 Pct, No Condensation; Relative Humidity (at 0 To +5 Deg C): 5 To 50 Pct, No Condensation; Change Of The Ambient Temperature: Less Than 0.5 Deg C/mint; Storage Temperature: -40 To +55 Deg C; Transport Temperature: -40 To +70 Deg C; Pollution Degree (iec 60664-1, Iec 60439-1): 2; Site Elevation Less Than 1000mr Above M.s.l: 100 Pct, Without Derating; Site Elevation 1000 To 4000 M.s.l: With Derating (1 Pct/100 Mr); Standard Duty Us 150%, 30 Sec, I2sd: 264 Amp Dc; Standard Duty Us 150%, 30 Sec, Psd: 150 Hp; Frame Size: D3; Ac Input Contactors 3-pole (no): A260-30-11-84; Short Circuit Current Rating: 65 Kamp
Item #: 0790271
CAT #: DCS800-S01-0315-05
UPC:
Company wide:
1,544 Items found