"886 scg"
260 Found
OZ Gedney
1 IN M/F SEALING FITTING
Item #: 0151504
CAT #: 0ZGEYDM100
UPC: 783126141344
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX NEMA4
Item #: 0912720
CAT #: GUEB7100AN4
UPC: 783126009590
Company wide:
Appleton
GUB FORM 3 THICK WALL UNILET
Item #: 0591939
CAT #: GUBB33A
UPC: 781381324526
Company wide:
Appleton
RDC BUSH ALUM 3TO1-1/4 IN NPT
Item #: 0561930
CAT #: RB300125A
UPC: 781381736541
Company wide:
OZ Gedney
3/4 IN M/F SEALING FITTING
Item #: 0151503
CAT #: 0ZGEYDM75
UPC: 783126141320
Company wide:
OZ Gedney
1 IN ALUM CLOSE-UP PLUG
Item #: 0223160
CAT #: 0ZGPLG100RA
UPC: 783126057041
Company wide:
Appleton
2 1/2 ALMAG 35 SEALING FITTING
Item #: 0440695
CAT #: EYM250AL
UPC: 781381600163
Company wide:
Appleton
JUNCTION BOX APPLETON TAG#88A
Item #: 0925468
CAT #: AJBEW091105
UPC: 781381846349
Company wide:
OZ Gedney
Sealing Fitting, Vertical/Horizontal, 1/2", Explosion-Proof, Malleable
Item #: 0045153
CAT #: EYA50
UPC: 783126138009
Company wide:
OZ Gedney
2-1/2 IN HOR/VERT SEALING FTG
Item #: 0151344
CAT #: EYA250
UPC: 783126138122
Company wide:
OZ Gedney
1 IN IRON VERT SEALING FTG
OZ-Gedney Type EY Vertical Sealing Fitting, Size: 1 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 1-5/8 IN Body Diameter X 4-3/8 IN Overall Length, 2-7/16 IN Turning Radius, 3.75 OZ Sealing Compound Required, 1/8 OZ Approximate Amount Of Fiber/Hub Required, Third Party Certification: UL File Number E-34997, UL Listed Using O-Z/Gedney EYC Sealing Compound Or Crouse-Hinds Chico Compound, UL Listed For Vertical Conduit Runs In: Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 009795, CSA Certified sealing compound, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 & 505, Military Specification: Mil-F-28675, For Rigid Conduit Or IMC
Item #: 0045160
CAT #: EY100
UPC: 783126137040
Company wide:
OZ Gedney
1 IN M/F SEALING FITTING
Explosion-Proof Conduit Drain and Seal Fitting, Type Drain, Turning Radius 2-1/16 Inch, Trade Size 1 Inch, Connection Type Male, Female, Material Zinc Electroplated Chromate Epoxy Powder Coated Ductile/Malleable Iron, Mounting Position Vertical, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, Approval UL 886, CSA C22.2, Overall Length 6-1/32 Inch, Application Seal Conduits in Vertical or Horizontal, to Minimize the Passage of Gases and Vapors and Prevent the Passage of Flames from One Portion of the Electrical System to Another Through the Conduit, Constructional Feature Explosion-Proof
Item #: 0151504
CAT #: 0ZGEYDM100
UPC: 783126141344
Company wide:
OZ Gedney
JUNCTION BOX
Explosion-Proof Junction Box, Hub Size 2 Inch, Overall Size 7 Inch L x 7 Inch W x 6.5 Inch D, Inner Size 6.13 Inch W x 4.25 Inch D x 6.13 Inch H, Wall Thickness 0.44 Inch (Side/Bottom), Cover Type Threaded, Cover Opening Diameter 5.94 Inch, Enclosure Class I Div 1 and 2 Group B C D Class II, Div 1 and 2 Groups E F G, Class III NEMA 4/4X/7BCD/9EFG, Body Material Copper-Free Aluminum, Body Finish Gray Epoxy Powder Coated, Cover Material Copper-Free Aluminum, Cover Finish Gray Epoxy Powder Coated, Mounting Feet, Approval UL 886, CUL, CSA C22.2, Application Hazardous Location, Material Neoprene (O-Ring)
Item #: 0765128
CAT #: NGUB664A
UPC: 783126082524
Company wide:
OZ Gedney
4 IN IRON UNION
Rigid Conduit Union, Type Female/Female, Material Zinc Electroplate/Chromate/Epoxy Powder Coat Malleable Iron, Trade Size 4 Inch, Diameter 6-7/16 Inch, Length 3-1/2 Inch, Approval UL 886, CSA C22.2, Applicable Standard NEC 500 to 503/505, Application Hazardous Location, Constructional Feature Explosion-Proof, Dust Ignitionproof, Enclosure Class I Div 1 2 Groups B C D, Class I Zone 1 2, Groups IIA IIB, Class II Div 1 2 Groups E F G, Class III
Item #: 0096609
CAT #: UNF400
UPC: 783126552188
Category:
Explosion-Proof Type UNF Unions
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX
OZ-Gedney Type GUAL Conduit Outlet Box, Number Of Outlet: 2, Malleable Iron Body, Copper-Free Aluminum Cover, Size: 3/4 IN, Cable Entry: (2) 3/4 IN Hubs, 15 CU-IN Capacity, No, 3 IN Cover Opening, Finish: Zinc Electroplated With Aluminum Enamel, 3-5/8 IN Width, 2-1/8 IN Depth, 3-5/8 IN Height, NEMA Rating: NEMA 4, 7CD, 9EFG, Third Party Certification: UL File Number E-30513, Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 020945, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 And 505, Military Specification Mil-F-28675, Federal Specification A-A-50563, For Rigid Conduit And IMC
Item #: 0045212
CAT #: GUAL75
UPC: 783126247213
Category:
Explosion-Proof L Conduit Outlet Boxes
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX NEMA4
OZ-Gedney Type GUEB Conduit Outlet Box, Number Of Outlet: 7, Copper-Free Aluminum, Size: 1 IN, Cable Entry: (7) 1 IN Hubs, 29 CU-IN Capacity, No, 3.38 IN Cover Opening, Finish: Aluminum Enamel, 4-5/8 IN Width, 3 IN Depth, 4-5/8 IN Height, NEMA Rating: NEMA 4, 7BCD, 9EFG, Third Party Certification: UL File Number E-30513, Class I, Division 1, 2, Groups B, C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 009795, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 And 505, Federal Specification A-A-50563, For Rigid Conduit And IMC
Item #: 0912720
CAT #: GUEB7100AN4
UPC: 783126009590
Company wide:
Appleton
GUB FORM 3 THICK WALL UNILET
UNILETS GUBB Cast Junction Box, Material: Malleable Iron, Size: 9.69 IN Cover Opening, Mounting: Lugs, Cubic Capacity: 455 CU-IN, Form Number: 3, Width: 12 IN, Depth: 7-3/4 IN, Height: 12 IN, Cover Opening: 9.69 IN, Standard: UL 886 (UL 1203), UL File Number E10444, CSA C22.2 No. 25, C22.2 No. 30, 025875 Certified, Class I, Division 1 And 2, Groups B, C, D, Class II, Division 1 And 2, Groups E, F, G, Class III, NEMA 7BCD, 9EFG, For Use With Unilets Threaded Metal Conduit
Item #: 0591939
CAT #: GUBB33A
UPC: 781381324526
Company wide:
Appleton
RDC BUSH ALUM 3TO1-1/4 IN NPT
Conduit Reducer Bushing, Type Threaded, Large End Trade Size 3 Inch, Small End Trade Size 1-1/4 Inch, Enclosure Class I Group A B C D, Class II Group E F G, Class III, Material Aluminum, Approval UL 886, CSA C22.2, Finish Natural, Used On Rigid Conduit/IMC
Item #: 0561930
CAT #: RB300125A
UPC: 781381736541
Category:
Aluminum Reducing Bushings
Company wide:
OZ Gedney
2 IN IRON VERT SEALING FTG
OZ-Gedney Type EY Vertical Sealing Fitting, Size: 2 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 2-3/4 IN Body Diameter X 6-1/4 IN Overall Length, 3-5/8 IN Turning Radius, 15 OZ Sealing Compound Required, 1 OZ Approximate Amount Of Fiber/Hub Required, Third Party Certification: UL File Number E-34997, UL Listed Using O-Z/Gedney EYC Sealing Compound Or Crouse-Hinds Chico Compound, UL Listed For Vertical Conduit Runs In: Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 009795, CSA Certified sealing compound, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 & 505, Military Specification: Mil-F-28675, For Rigid Conduit Or IMC
Item #: 0045163
CAT #: EY200
UPC: 783126137101
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX
OZ-Gedney Type GUAL Conduit Outlet Box, Number Of Outlet: 2, Malleable Iron Body/Cover, Size: 1-1/2 IN, Cable Entry: (2) 1-1/2 IN Hubs, 70 CU-IN Capacity, No, 5-1/8 IN Cover Opening, Finish: Zinc Electroplated With Aluminum Enamel, 5-5/8 IN Width, 3-3/4 IN Depth, 5-5/8 IN Height, NEMA Rating: NEMA 4, 7CD, 9EFG, Third Party Certification: UL File Number E-30513, Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 020945, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 And 505, Military Specification Mil-F-28675, Federal Specification A-A-50563, For Rigid Conduit And IMC
Item #: 0369770
CAT #: GUAL150
UPC: 783126247244
Category:
Explosion-Proof L Conduit Outlet Boxes
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX
OZ-Gedney Type GUAX Conduit Outlet Box, Number Of Outlet: 4, Malleable Iron Body/Cover, Size: 1-1/4 IN, Cable Entry: (4) 1-1/4 IN Hubs, 30 CU-IN Capacity, No, 3-3/4 IN Cover Opening, Finish: Zinc Electroplated With Aluminum Enamel, 4-1/4 IN Width, 3 IN Depth, NEMA Rating: NEMA 4, 7CD, 9EFG, Third Party Certification: UL File Number E-30513, Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 020945, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 And 505, Military Specification Mil-F-28675, Federal Specification A-A-50563, For Rigid Conduit And IMC
Item #: 0151517
CAT #: GUAX125
UPC: 783126247534
Category:
Explosion-Proof X Conduit Outlet Boxes
Company wide:
OZ Gedney
3/4 IN M/F SEALING FITTING
Explosion-Proof Conduit Drain and Seal Fitting, Type Drain, Turning Radius 1-15/16 Inch, Trade Size 3/4 Inch, Connection Type Male, Female, Material Zinc Electroplated Chromate Epoxy Powder Coated Ductile/Malleable Iron, Mounting Position Vertical, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, Approval UL 886, CSA C22.2, Overall Length 5-5/32 Inch, Application Seal Conduits in Vertical or Horizontal, to Minimize the Passage of Gases and Vapors and Prevent the Passage of Flames from One Portion of the Electrical System to Another Through the Conduit, Constructional Feature Explosion-Proof
Item #: 0151503
CAT #: 0ZGEYDM75
UPC: 783126141320
Company wide:
Appleton
PLUG 3 SQR HEAD CLOSE-UP
UNILETS Square Head Close-Up Plug, Size: 3 IN, Material: Malleable Iron, Finish: Zinc Electroplate, Connection: Tapered MNPT, Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 25 And 30, CSA 065181, UL Listed For Class I, Gro
Item #: 0078791
CAT #: PLG300S
UPC: 781381652605
Company wide:
OZ Gedney
3/4 IN HAZ LOC COND BODY LB
OZ-Gedney Type OELB Conduit Outlet Body, 3/4 IN Hub, Iron, Finish: Zinc Electroplated With Aluminum Enamel, Gray, Connection: Threaded, Third Party Certification: UL File Number E-30513, CSA 009795, Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, Applicable Third Party Standards: UL 886, CSA C22.2 No. 30, Federal Specification Number A-A-50563, NEC Articles 500-503 And 505, Mil. Specification: Mil-F-28675, For Rigid Conduit And IMC
Item #: 0137981
CAT #: 0ELB75
UPC: 783126055467
Category:
Explosion-Proof Type LB Conduit Bodies
Company wide:
OZ Gedney
1 IN ALUM CLOSE-UP PLUG
OZ-Gedney Type PLG Internal Recessed Threaded Insert Plug, Size: 1 IN, Copper-Free Aluminum, Connection: Threaded NPT, Body Thick: 3/4 IN, 1/2 IN Socket Size, Third Party Certification: UL File Number E-34997 Suitable For Wet Locations, UL Listed For Hazardous Location Use As Follows: Class I, Division 1, 2, Groups A, B, C, D, Class I, Zone 1, 2, Groups IIA, IIB, IIC, Class II, Division 1, 2, Groups E, F, Glass III, CSA 009795, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 & 505, For Outlet Boxes And Hubs
Item #: 0223160
CAT #: 0ZGPLG100RA
UPC: 783126057041
Company wide:
Appleton
3/4 EXJF FLEXIBLE HANGER
Explosion-Proof Flexible Fixture Hanger, Constructional Feature Explosion-Proof, Dust Ignitionproof, Raintight, Trade Size 3/4 IN, Flex Length 12 IN, Overall Length 19.06 IN, Material Brass Inner Core, Bronze Outer Braid, Brass End Fitting, Finish Natural, Enclosure Class I Div 1 and 2 Group A B C D, Class II Div 1 and 2 Group E F G, Class III, Approval UL E10444/886, CSA, Inclusion (2) Female Hub, Removable Close Nipple, Setscrew, Maximum Load 120 LBS
Item #: 0611603
CAT #: EXJF212
UPC: 781381108065
Category:
Explosion-Proof Type EXJF Couplings
Company wide:
OZ Gedney
PUSHBUTTON BLK 1NO-1NC SHORT
Explosion-Proof Non-Illuminated Pushbutton, Type Short Barrel, Operation Type Momentary, Contact Configuration 1NO-1NC, Contact Rating 600 VAC, Cap/Lens Color Black, Enclosure Material Copper-Free Aluminum, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, NEMA 4/7BCD/9EFG, Approval UL 886, CSA C22.2, Connection Size 3/4 Inch NPSM, Constructional Feature Explosion-Proof, Application Hazardous Location
Item #: 0375887
CAT #: NEPBE
UPC: 783126979336
Company wide:
Appleton
ADPTR MALE/FEMALE 1 NPT
Cable Gland Adapter, Type Threaded, Large End Trade Size 1 Inch, Small End Trade Size 1 Inch, Material Nickel Plated Brass, Approval UL 886, CSA C22.2, CE, ATEX/IECEx, Used On Cable Gland, Application Hazardous Location, Constructional Feature Flameproof, Enclosure Type Class I Group A B C D Zone 1 AEx de II, IP66/IP68, Temperature Rating -60 to 100 Deg C
Item #: 0385372
CAT #: 737DT3T35
UPC: 781381136716
Category:
Metric Cable Gland Adapters
Company wide:
Appleton
2 1/2 ALMAG 35 SEALING FITTING
Explosion-Proof Rigid/IMC Conduit Seal, Turning Radius 2.69 Inch, Trade Size 2-1/2 Inch, Connection Type Male, Female, Material Epoxy Powder Coated Almag 35 Aluminum, Mounting Position Horizontal/Vertical, Enclosure Class I Div 1 and 2 Group A B C D, Class II Div 1 and 2 Group E F G, Class III, Approval UL 886/E10444, CSA C22.2, Size 7.5 Inch L x 3.38 Inch W, Constructional Feature Explosion-Proof, Dust-Ignitionproof, Raintight, Used On Threaded Rigid/IMC Metal Conduit, Includes Removable Male Nipple
Item #: 0440695
CAT #: EYM250AL
UPC: 781381600163
Company wide:
Appleton
JUNCTION BOX APPLETON TAG#88A
Explosion-Proof Junction Box, Hub Size 2 Inch, Overall Size 15.5 Inch L x 13.88 Inch W x 8.69 Inch D, Inner Size 11.13 Inch L x 9 Inch W x 4.81 Inch D, Cover Type Bolt-On, Hinged, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, NEMA 4/9EFG, IP66, Body Material Sand Cast Copper-Free Aluminum, Body Finish Shot Blast, Cover Material Sand Cast Copper-Free Aluminum, Cover Finish Shot Blast, Mounting Horizontal/Vertical with Slotted Feet, Approval UL 886, CSA C22.2, Application Hazardous Location, Used On Terminal, Splicing wire, Pull box, Bus box, Includes Stainless Steel Cover Bolt, Neoprene O-Ring, Galvanized Steel Mounting Pan
Item #: 0925468
CAT #: AJBEW091105
UPC: 781381846349
Company wide:
OZ Gedney
Sealing Fitting, Vertical/Horizontal, 1/2", Explosion-Proof, Malleable
Features: Length 4 1/32 In, Application: Rigid Conduit, Imc, Standard: Ul 886, Csa C22.2, Nec, Size: 0.5in, Material: Copper Free Aluminum
Item #: 0045153
CAT #: EYA50
UPC: 783126138009
Company wide:
OZ Gedney
2-1/2 IN HOR/VERT SEALING FTG
OZ-Gedney Type EYA Vertical/Horizontal Sealing Fitting, Size: 2-1/2 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 2-3/4 IN Body Diameter X 7-1/4 IN Overall Length, 3-1/4 IN Turning Radius, 1 LB 3 OZ Sealing Compound Required, 1-1/2 OZ Approximate Amount Of Fiber/Hub Required, Third Party Certification: UL File Number E-34997, CSA 009795 Suitable For Wet Locations, UL Listed Using: O-Z/Gedney EYC Sealing Compound Or Crouse-Hinds Chico Compound, CSA Certified Sealing Compound, Class I, Division 1, 2, Groups B, C, D, Class I, Zone 1, 2, Groups IIA, IIB + H2, Class II, Division 1, 2, Groups E, F, G, Class III, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30 NEC Articles 500-503 & 505, Military Specification: Mil-F-28675, For Rigid Conduit Or IMC
Item #: 0151344
CAT #: EYA250
UPC: 783126138122
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX
OZ-Gedney Type GUAL Conduit Outlet Box, Number Of Outlet: 2, Malleable Iron Body, Copper-Free Aluminum Cover, Size: 1 IN, Cable Entry: (2) 1 IN Hubs, 17 CU-IN Capacity, No, 3 IN Cover Opening, Finish: Zinc Electroplated With Aluminum Enamel, 3-5/8 IN Width, 2-3/8 IN Depth, 3-5/8 IN Height, NEMA Rating: NEMA 4, 7CD, 9EFG, Third Party Certification: UL File Number E-30513, Class I, Division 1, 2, Groups C, D, Class I, Zone 1, 2, Groups IIA, IIB, Class II, Division 1, 2, Groups E, F, G, Class III, CSA 020945, Applicable Third Party Standards: UL 886, CSA C22.2 Number 30, NEC Articles 500-503 And 505, Military Specification Mil-F-28675, Federal Specification A-A-50563, For Rigid Conduit And IMC
Item #: 0369760
CAT #: GUAL100
UPC: 783126247220
Category:
Explosion-Proof L Conduit Outlet Boxes
Company wide:
OZ Gedney
HAZ LOC COND OUTL BX CSA
Explosion-Proof Conduit Outlet Box, Style LB, Hub Size 3/4 Inch, Hub Type External, Number of Hubs 2, Hub Location (1) Side, (1) Down, Capacity 15 Cu Inch, Shape Round, Cover Type Internally Threaded, Cover Opening Diameter 3 Inch, Enclosure Class I Div 1 and 2 Group B C D, Class I Zone 1 and 2 Group IIA IIB, Class II Div 1 and 2 Group E F G, Class III, NEMA 3/4, Material Zinc Electroplated Malleable Iron, Approval UL 886, CSA C22.2, Applicable Standard NEC, Application Pulling of Wires, Wet Location, Constructional Feature Explosion-Proof, Dust Ignitionproof, Includes Ground Screw/Lug
Item #: 0369977
CAT #: GUJLB75CS
UPC: 783126068986
Category:
Explosion-Proof LB Conduit Outlet Boxes
Company wide:
260 Items found