"l4t5b/840/25/f/se-70"
92 Found
ABB
Softstarter, 206A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366950
CAT #: PSTX720-690-70
UPC:
Company wide:
ABB
GED PSRC30-600-70 PSRC30 600V
Item #: 0365628
CAT #: PSRC30-600-70
UPC: 320500465537
Company wide:
ABB
Softstarter, 60A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366946
CAT #: PSTX60-690-70
UPC: 320500501372
Company wide:
ABB
Softstarter, 105A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366932
CAT #: PSTX105-690-70
UPC:
Company wide:
ABB
Softstarter, 1050A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366931
CAT #: PSTX1050-690-70
UPC:
Company wide:
ABB
Softstarter, 470A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366947
CAT #: PSTX470-690-70
UPC:
Company wide:
ABB
Softstarter, 72A, 208 - 600VAC, 100 - 250VAC Control, 3PH
Item #: 1018245
CAT #: PSTX72-690-70
UPC: 888614237407
Company wide:
ABB
Softstarter, 250A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366939
CAT #: PSTX250-690-70
UPC: 888614237490
Company wide:
ABB
Softstarter, 570A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366948
CAT #: PSTX570-690-70
UPC:
Company wide:
ABB
Softstarter, 370A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366942
CAT #: PSTX370-690-70
UPC: 320500501525
Company wide:
ABB
Softstarter, 170A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366936
CAT #: PSTX170-690-70
UPC: 888614237452
Company wide:
ABB
Softstarter, 1250A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Item #: 0366933
CAT #: PSTX1250-690-70
UPC:
Company wide:
ABB
Softstarter, 1250A, 3PH, 24VDC Coil
Item #: 0185187
CAT #: PSTX1250-600-70
UPC: 888614461512
Company wide:
Discontinued
ABB
PSE, Softstart, 302 FLA, 248 FLA.
Item #: 0888154
CAT #: PSE300-600-70
UPC: 804325571708
Company wide:
ABB
PSE, Softstart, 248 FLA, 192 FLA.
Item #: 0873659
CAT #: PSE250-600-70
UPC: 804325571692
Company wide:
ABB
PSE, Softstart, 192 FLA, 169 FLA.
Item #: 0888153
CAT #: PSE210-600-70
UPC: 804325571685
Company wide:
ABB
Softstarter, 206A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX720-690-70 has a rated maximum operational current of 720 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.
Item #: 0366950
CAT #: PSTX720-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
PSR, Softstarter, 80 FLA
PSR Series Softstart (Compact style). 80 FLA (Full Load Amps). Motor Voltage: 208V - 600V AC. Control Voltage: 120V - 240V AC. Din-Rail/Screw Mountable. Requires: TA75 Series Overload Protection & DB80 Series Mounting Kit.
Item #: 0791362
CAT #: PSR85-600-70
UPC: 320500362638
Category:
Basic Control Softstarters
Company wide:
ABB
GED PSRC30-600-70 PSRC30 600V
ABB PSRC3060070 PSRC SSTR 600
Item #: 0365628
CAT #: PSRC30-600-70
UPC: 320500465537
Category:
Basic Control Softstarters
Company wide:
ABB
Softstarter, 60A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX60-690-70 has a rated maximum operational current of 60 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366946
CAT #: PSTX60-690-70
UPC: 320500501372
Category:
Advanced Control Softstarters
Company wide:
ABB
Psr Sstr,600v/240vac,3.4a
Psr Sstr,600v/240vac,3.4a
Item #: 0695860
CAT #: PSR3-600-70
UPC: 662019261362
Category:
Basic Control Softstarters
Company wide:
ABB
Softstarter, 105A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX105-690-70 has a rated maximum operational current of 105 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366932
CAT #: PSTX105-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 1050A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX1050-690-70 has a rated maximum operational current of 1050 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.
Item #: 0366931
CAT #: PSTX1050-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 470A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX470-690-70 has a rated maximum operational current of 470 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366947
CAT #: PSTX470-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 72A, 208 - 600VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX72-690-70 has a rated maximum operational current of 72 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 1018245
CAT #: PSTX72-690-70
UPC: 888614237407
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 250A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX250-690-70 has a rated maximum operational current of 250 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366939
CAT #: PSTX250-690-70
UPC: 888614237490
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 570A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX570-690-70 has a rated maximum operational current of 570 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366948
CAT #: PSTX570-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
Psr Sstr,600v/240vac,72a
Psr Sstr,600v/240vac,72a
Item #: 0841712
CAT #: PSR72-600-70
UPC: 320500362614
Category:
Basic Control Softstarters
Company wide:
ABB
Softstarter, 370A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX370-690-70 has a rated maximum operational current of 370 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366942
CAT #: PSTX370-690-70
UPC: 320500501525
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 170A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX170-690-70 has a rated maximum operational current of 170 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366936
CAT #: PSTX170-690-70
UPC: 888614237452
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 1250A, 208 - 690VAC, 100 - 250VAC Control, 3PH
Softstarter PSTX1250-690-70 has a rated maximum operational current of 1250 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard
Item #: 0366933
CAT #: PSTX1250-690-70
UPC:
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter
Softstarter for Max 600V Main Voltage, 100-250V 50/60Hz Control Supply Voltage
Item #: 1896497
CAT #: PSE250-600-70-1
UPC: 320500515034
Category:
Advanced Control Softstarters
Company wide:
ABB
Softstarter, 600V
Softstarter, 600 Volt Main Voltage, 100-250 Volt Control Supply Voltage, 50/60 Hz, 370 Amps
Item #: 1896499
CAT #: PSE370-600-70-1
UPC: 320500515058
Category:
Advanced Control Softstarters
Company wide:
ABB
PSR, Softstarter, 104 FLA
PSR Series Softstart (Compact style). 104 FLA (Full Load Amps). Motor Voltage: 208V - 600V AC. Control Voltage: 120V - 240V AC. Din-Rail/Screw Mountable. Requires: TA75 Series Overload Protection & DB80 Series Mounting Kit.
Item #: 0792277
CAT #: PSR10560070
UPC: 320500362652
Category:
Basic Control Softstarters
Company wide:
Eaton
Soft Starter Controller
Soft Start Controller, 3-pole, 25 Amp, Line Voltage: 400 - 480 Vac, Control Voltage: 24 - 240 Vac/vdc
Item #: 0464612
CAT #: S701E25N3S
UPC: 782114818794
Category:
Basic Control Softstarters
Company wide:
ABB
Softstarter, 1250A, 3PH, 24VDC Coil
PSTX Series Softstart (New Advanced Range). Motor Voltage: 208 - 600V AC. Supply Voltage: 100 - 250V AC. Control Voltage: 24V DC, Supplied by Softstart or External Supply. Normal Duty: 1250 FLA (Full Load Amps). Heavy Duty: 1062 FLA (Full Load Amps). Includes: Removable Remote Mountable Digital Key-Pad, Integrated RS485 Modbus RTU, Anybus FieldBus Communication Slot, (1) PTC Motor Temp Input, (1) Analog Output, (3) Programmable Signal Relays, Programmable Overload Protection, and Integrated Bypass. 17 Inch Width, 22 Inch Height, 14 Inch Depth Weight: 140Lbs.
Item #: 0185187
CAT #: PSTX1250-600-70
UPC: 888614461512
Category:
Advanced Control Softstarters
Company wide:
Discontinued
ABB
PSE, Softstart, 302 FLA, 248 FLA.
PSE Series Softstart (Compact Style.) Motor Voltage: 208V-600V AC. Control Voltage: 120V-240V AC. Normal Duty: 302 FLA (Full Load Amps). Heavy Duty: 248 FLA (Full Load Amps). Screw Mount. Includes: Digital Keypad, Optional FieldBus Communication, Overload Protection and By-Pass. ***Lugs Required, See Associated Items For Lugs***
Item #: 0888154
CAT #: PSE300-600-70
UPC: 804325571708
Category:
Advanced Control Softstarters
Company wide:
ABB
PSE, Softstart, 248 FLA, 192 FLA.
PSE Series Softstart (Compact Style.) Motor Voltage: 208V-600V AC. Control Voltage: 120V-240V AC. Normal Duty: 248 FLA (Full Load Amps). Heavy Duty: 192 FLA (Full Load Amps). Screw Mount. Includes: Digital Keypad, Optional FieldBus Communication, Overload Protection and By-Pass. ***Lugs Required, See Associated Items For Lugs***
Item #: 0873659
CAT #: PSE250-600-70
UPC: 804325571692
Category:
Advanced Control Softstarters
Company wide:
ABB
PSE, Softstart, 192 FLA, 169 FLA.
PSE Series Softstart (Compact Style.) Motor Voltage: 208V-600V AC. Control Voltage: 120V-240V AC. Normal Duty: 192 FLA (Full Load Amps). Heavy Duty: 169 FLA (Full Load Amps). Screw Mount. Includes: Digital Keypad, Optional FieldBus Communication, Overload Protection and By-Pass. ***Lugs Required, See Associated Items For Lugs***
Item #: 0888153
CAT #: PSE210-600-70
UPC: 804325571685
Category:
Advanced Control Softstarters
Company wide:
Eaton
S611, Lug Kit, Frame E/F
Lug Kit, (2) 2 AWG - 600 MCM, For use with S611 Series Frame E & F, 302 - 414 Amp Softstarters. Includes: 3 Lugs that can be used on the Line Side or Load Side.
Item #: 0913011
CAT #: S611-LUG-M04
UPC: 786685480572
Category:
Softstarter Lug Kits
Company wide:
92 Items found